Properly kept fire protection documentation is a legal obligation and also one of the first documents the fire rescue service and the insurer want to see after a fire.
We prepare drawings and fire-fighting documentation (DZP), fire safety designs (PBŘ) and extensive fire protection and organisational systems for large sites and operations – from a single building to an entire company with dozens of buildings. DZP · PBŘ · PPN · Evacuation plans
What we provide
Fire protection documentation
Classification of activities as without increased, with increased or with high fire hazard (Act No. 133/1985 Coll.) and a fire hazard assessment
Fire regulations, fire alarm instructions, fire reporting point rules and other documentation under Decree No. 246/2001 Coll.
Fire-fighting documentation – operational plans and cards including the graphic part
Training and professional preparation records, keeping the fire log book
Drawings, plans and building passports
Fire protection drawings – escape routes, fire extinguishers, hydrants, main water, gas and electricity shut-offs, switchboards
Passports of buildings and fire safety equipment – an overview of all equipment, its location, inspections and deadlines
Safety signage for escape routes and fire safety equipment – produced and installed express via safetyznacky.cz
Fire safety design (PBŘ)
Fire safety design of a building for alterations, changes of use or leases – in cooperation with an authorised person
Assessment of compliance of the actual state with the fire safety design – in practice, operations often differ from the approved documentation. More about fire safety design →
Equipment proposal – fire extinguishers, hydrants and other means
Fire-fighting documentation (DZP) and drawings
Preparation of DZP – operational plans and operational cards, fire and site drawings, access routes and set-up areas, firefighting water sources, shut-offs and switchboards
Graphic part in CAD – clear drawings in the format used by the fire rescue service and a digital version available to responding units
Approval and updates – cooperation with the regional fire rescue service, changes when rebuilding, storing new materials or changing technology
Extensive fire protection and organisational systems
Large-scale fire safety equipment – fire detection and alarm systems, fixed fire suppression systems, smoke and heat exhaust, fire water mains and hydrant systems; concept design, passports and inspections
Fire protection management systems for large companies – setting up fire protection management across a group, a uniform directive, fire prevention officers, fire patrols, training system and inspection rules
Passports for hundreds of buildings and installations with deadline tracking in the EKODAV SAFETY app
Preventive fire inspections with an entry in the fire log book
Fire prevention officer and fire patrols – selection, professional preparation and support
Fire alarm and evacuation drills
Tracking inspection deadlines for fire extinguishers, hydrants and fire safety equipment – fire alarm systems, sprinklers, fire doors and dampers
Activities with an increased fire risk – welding, storage of flammables
Fire protection training for employees and managers – classroom and online
Training and practical testing of fire systems
Our cooperation is not just paperwork. We provide proper training with the responsible persons – fire prevention officers, fire patrols, managers and equipment operators – from practical demonstrations up to demanding verification of fire systems under real conditions.
Practical demonstrations and drills – extinguishers and hydrants, operating fire alarm panels and call points, utility shut-offs, raising the alarm
Fire alarm and evacuation drills including evaluation and recommended measures
Extreme verification of fire systems that a landlord or building owner may require – interaction of fire detection, sprinklers, smoke and heat exhaust, fire doors, dampers and lifts
Tests of the fire safety design – verifying that the building and equipment really work in operation as the fire safety design assumes, including coordinated functional tests
Report and recommendations – a clear output for the owner, tenant, insurer and fire rescue service
Fire stopping
We work with several suppliers of certified fire-stopping systems, so we can choose a solution to suit the structure, penetration and required fire resistance. We both install and inspect fire stopping.
Installation of fire stopping for cable, pipe and ductwork penetrations through fire-separating structures
Operability inspections and a register of fire stops with photos and labelling
Repairs and additions after building works, when fire stops are most often damaged
Documents for approval, the fire rescue service and insurers – declarations of performance, labels and reports
After a fire
Cooperation with the fire rescue service in determining the causes
Documentation for the insurer, expert opinions and analyses of the causes and course of the fire
Restoring operations and new fire protection documentation
Why fire protection matters even in offices
Some obligations – such as fire extinguishers, clear escape routes or regular equipment checks – apply to practically every company. The extent of the documentation depends on the fire hazard category, so correct classification of activities is the first step.
Frequently asked questions
How often must fire extinguishers be checked?
Under Decree No. 246/2001 Coll., the operability check of portable fire extinguishers is usually carried out once a year, unless the manufacturer or operating conditions require a shorter interval. Only a competent person may carry out the check.
Who needs fire protection documentation?
Primarily operators of activities with increased or high fire hazard. For activities without increased hazard the obligations are fewer, but some (e.g. fire extinguishers and equipment maintenance) still apply. We will help you determine the correct classification.
What is a preventive fire inspection?
A regular check of compliance with fire protection regulations at the workplace – the condition of escape routes, fire extinguishers, electrical installations, storage of flammables and more. It is carried out at intervals given by the fire hazard category and the result is recorded in the fire log book.